Service
Get server CPU back for applications, on hardware that performs on your traffic
We move the costliest packet processing, virtual switching, overlays, firewalling and encryption, from server CPU to SmartNICs, DPUs or FPGAs. The work starts by measuring candidate hardware on your own traffic profile with RFC 2544 methodology and tuning the software data path, and the offload runs as a pilot with acceptance criteria agreed up front.
Measured impact
What changes for your organization
- Today
Server CPU spent on the network
Virtual switching, overlays and encryption run in software on the host and take cores the applications were bought for.
With the offloadCPU back for applications
Packet processing moves to the NIC, SmartNIC or DPU that handles it best, and the freed cores go back to workloads.
- Today
Hardware chosen from datasheets
Vendor figures come from vendor test setups, and the card or switch behaves differently once your packet sizes, flows and features run on it.
With the offloadA purchase backed by results
Every candidate is measured on your traffic profile with the same method, so the money goes to the hardware that performs where you need it.
- Today
Results nobody can compare
Each test run uses a different setup, and the test environment itself distorts latency and loss, so the numbers start arguments.
With the offloadRepeatable, comparable numbers
A verified testbed, RFC 2544 methodology and automated reports give the same answer on every run, for engineers and for the business.
- Today
Acceleration as a leap of faith
An offload project starts with a vendor promise, and its real gain is known only after the rollout.
With the offloadA pilot with a pass mark
The acceptance criteria are agreed before the pilot starts, so the decision to roll out rests on measured gain.
- Today
Slowdowns found late
Full performance runs are slow and run rarely, so a regression in firmware or drivers surfaces close to production.
With the offloadRegressions caught early
Benchmarks run in CI/CD on every firmware and driver release, so a slowdown is caught where a fix costs least.
What we deliver
How it runs
A hardware choice and an offload pilot follow the same order; the pilot adds the build and the integration.
Discovery
Your workloads, traffic and hardware plans, the question the evaluation answers, and the acceptance criteria and plan.
Traffic profile and testbed
Your traffic profile written down, and the testbed built as code and verified before it measures anything.
Baseline
Today’s hardware and software data path measured, then tuned, so every gain is set against a fair start.
Benchmark or pilot
Candidate hardware benchmarked on your profile, or the chosen function offloaded to a SmartNIC or DPU and integrated.
Report
Results against the acceptance criteria, in a technical and a business version, with the recommendation.
Handover
The benchmark suite in your CI/CD, documented, and our support for the rollout for as long as you want it.
Two ways in
Most clients come with one of two questions. Both start with the same measurement; the offload adds the build.
Offload pilot
Your servers spend CPU on networking or encryption. We tune the software path, move the costliest function to a SmartNIC or DPU, and measure the gain against agreed criteria.
Hardware benchmark
You are choosing new NICs, SmartNICs, DPUs or switches. We measure the candidates on your traffic profile and recommend the one that performs, ready for the offload.
Proof
- SDN dataplane offloading for telco clouds: 18 cores down to 2For a SmartNIC manufacturer, the Tungsten Fabric vRouter data plane offloaded to FPGA SmartNICs, deployable through OpenStack and Kubernetes, with an RFC 2544 test framework in CI/CD.
- Benchmarking SmartNICs to RFC 2544 with open-source traffic generation and automated reportingOur framework for hardware vendors: a testbed as code, layered device testing, RFC 2544 runs scheduled in Jenkins and reports for engineers and business teams.
- A 100 Gbps security dataplane on a DPU with 0% host CPUFor a security vendor, Kubernetes policies enforced inline on NVIDIA BlueField DPUs at line rate, with the host left to its AI workloads.
- Offloading VNFs to P4-programmable SmartNICs with an ONOS SDN controllerFor a data center provider, a firewall VNF moved to a P4 SmartNIC in a proof of concept, managed by the same SDN controller as the rest of the network.
